RayonixHs Tango device

This is the reference documentation of the RayonixHs Tango device.

you can also find some useful information about the camera models/prerequisite/installation/configuration/compilation in the RayonixHs camera plugin section.

Properties

Property name

Mandatory

Default value

Description

frame_mode

No

single

The frame mode, single or fast_transfer

frame_trigger_signal_type

No

opto

The frame trigger signal type (input #1)

sequence_gate_signal_type

No

opto

The gate signal type (input #2)

electronic_shutter_enabled

No

false

The electronic shutter true or false to activate or not

cooler_temperature_setpoint

No

-120

The cooling system temperature setpoint in Celsuis

sensor_temperature_setpoint

No

-80

The detector (sensor) temperature setpoint in Celsuis

output1_signal_type

No

cmos

The output #1 signal type

output2_signal_type

No

cmos

The output #2 signal type

output1_id

No

shutter

The output #1 signal source

output2_id

No

frame

the output #2 signal source

The Rayonix HS input/output system supports different type of signals:
  • OPTO/OPTO_INVERTED/CMOS/CMOS_PULLDOWN/CMOS_PULLUP/CMOS_PULLDOWN_INVERTED/CMOS_PULLUP_INVERTED

And it provides a output multiplexer for both outputs within the following list of sources:
  • SHUTTER/INTEGRATE/FRAME/LINE/SHUTTER_OPENING/SHUTTER_CLOSING/SHUTTER_ACTIVE/TRIGGER_RISE_WAIT/TRIGGER_RISE_ACK/TRIGGER_FALL_WAIT/TRIGGER_FALL_ACK/TRIGGER_2_RISE_WAIT/TRIGGER_2_RISE_ACK/INPUT_FRAME/INPUT_GATE

Attributes

Attribute name

RW

Type

Description

frame_mode

rw

DevString

The frame mode, single or fast_transfer

frame_trigger_signal_type

rw

DevString

The frame trigger signal type (input #1)

sequence_gate_signal_type

rw

DevString

The gate signal type (input #2)

electronic_shutter_enabled

rw

DevString

The electronic shutter true or false to activate or not

cooler_temperature_setpoint

rw

DevDouble

The cooling system temperature setpoint in Celsuis

sensor_temperature_setpoint

rw

DevDouble

The detector (sensor) temperature setpoint in Celsuis

output1_signal_type

rw

DevString

The output #1 signal type

output2_signal_type

rw

DevString

The output #2 signal type

output1_id

rw

DevString

The output #1 signal source

output2_id

rw

DevString

The output #2 signal source

vacuum_valve

rw

DevString

The vacuum valve command true or false to open or close

Warning: be careful with the temperature setting (and vacuum valve), the operating temperature is factory-determined and should never be changed. There is no reason to run the detector at a warner temperature.

For the signal type and source the possible values are listed above in the Properties section.

Commands

Command name

Arg. in

Arg. out

Description

Init

DevVoid

DevVoid

Do not use

State

DevVoid

DevLong

Return the device state

Status

DevVoid

DevString

Return the device state as a string

getAttrStringValueList

DevString: Attribute name

DevVarStringArray: String value list

Return the authorized string value list for a given attribute name