Dhyana Tango device

This is the reference documentation of the Dhyana Tango device.

you can also find some useful information about the camera models/prerequisite/installation/configuration/compilation in the Dhyana camera plugin section.

Properties

Property name

Mandatory

Default value

Description

internal_trigger_timer

No

999

Soft timer to generate software trigger in millisecond.

temperature_target

No

n/a

To start cooling the detector (C)

trigger_mode

No

STANDARD

Tucam trigger mode:
  • STANDARD

  • GLOBAL

  • SYNCHRONOUS

trigger_edge

No

RISING

To set the trigger level:
  • RISING

  • FALLING

Attributes

Attribute name

RW

Type

Description

global_gain

rw

DevString

Global gain setting on the sensor, HDR, HIGH or LOW

fan_speed

rw

DevUShort

FAN speed for cooling, from 0 to 10

temperature

ro

Devdouble

Temperature of the sensor

temperature_target

rw

Devdouble

Temperature target

firmware_version

ro

DevString

Firmware version

tucam_version

ro

DevString

TUCAM SDK version

trigger_mode

rw

DevString

Tucam trigger mode: STANDARD, GLOBAL or SYNCHRONOUS

trigger_edge

rw

DevString

To set the input trigger level: RISING or FALLING

Commands

Command name

Arg. in

Arg. out

Description

Init

DevVoid

DevVoid

Do not use

State

DevVoid

DevLong

Return the device state

Status

DevVoid

DevString

Return the device state as a string

getAttrStringValueList

DevString: Attribute name

DevVarStringArray: String value list

Return the authorized string value list for a given attribute name